Steel-frame construction Vertical application method (furring strips)

Introducing vertically applied Hebel LiteTM standard fitting on furring strips of steel-frame construction.


Outline drawing

Outline drawing


Hebel LiteTM short-term allowable load (with steel-frame construction)

1800ŚLong panels used Span l = 900mm l = 600mm l = 450mm
Positive pressure 1373N/m2 3236N/m2 5786N/m2
Negative pressure 1373N/m2 2452N/m2 3138N/m2
2000ŚLong panels used Span l = 1000mm l = 666mm l = 500mm
Positive pressure 1177N/m2 2648N/m2 4707N/m2
Negative pressure 1177N/m2 2157N/m2 2844N/m2
Ś Panel length illustrated for standard method of use. Even if panel length differs, allowable load for each span remains the same.


Installation detail

Parapet


Mid-portion of beam


Foundation


Corner

External corners
 
(Corner panels used)   (General panels used)

Internal corners    
 
   

Return to top of page